{"product_id":"thermostat-for-pipe-heat-tape","title":"MAXKOSKO Pipe Heat Tape Thermostat Controller, 120V\/240V, 15 ft Sensor","description":"\u003cdiv class=\"mk-product-content\"\u003e\n\u003c!-- ==============================\nOverview\n============================== --\u003e\n\u003cdiv class=\"mk-overview\"\u003e\n\u003ch2\u003ePipe Heat Tape Thermostat Controller — 120V \/ 240V\u003c\/h2\u003e\n\u003cp\u003eAutomatic temperature control for compatible external and in-pipe heating cable systems.\u003c\/p\u003e\n\u003cul class=\"mk-list\"\u003e\n\u003cli\u003eChoose \u003cstrong\u003e120V plug-in\u003c\/strong\u003e or \u003cstrong\u003e208–240V hardwired\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eAdjustable from 36°F to 86°F (2°C to 30°C).\u003c\/li\u003e\n\u003cli\u003e15 ft remote sensor measures the pipe temperature.\u003c\/li\u003e\n\u003cli\u003eMaximum load: 15A.\u003c\/li\u003e\n\u003cli\u003eHeating cable is sold separately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"mk-feature-grid\"\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003eTwo Voltage Options\u003c\/h3\u003e\n\u003cp\u003e120V plug-in for simple installation. 208–240V hardwired for compatible higher-voltage systems.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003e15 ft Remote Sensor\u003c\/h3\u003e\n\u003cp\u003ePlace the sensor against the protected pipe for pipe-surface temperature control.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003eAdjustable Temperature\u003c\/h3\u003e\n\u003cp\u003eSelect a temperature from 36°F to 86°F (2°C to 30°C).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003e15A Maximum Load\u003c\/h3\u003e\n\u003cp\u003eUp to 1800W at 120V, 3120W at 208V, or 3600W at 240V.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003eAutomatic Operation\u003c\/h3\u003e\n\u003cp\u003eSwitches power according to the temperature detected by the remote sensor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003ePower-Outage Memory\u003c\/h3\u003e\n\u003cp\u003eRetains the previous power status and temperature setting after power is restored.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-inline-media\"\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0733\/9684\/6865\/files\/1_4a1fdc82-b56f-45ca-92b5-0f0a6f4938b0.jpg?v=1734942476\" alt=\"MAXKOSKO pipe heating cable thermostat controller with remote temperature sensor\" loading=\"lazy\" style=\"display: block; width: 100%; height: auto; margin: 0 0 18px;\" decoding=\"async\"\u003e\u003c\/figure\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0733\/9684\/6865\/files\/2_7fe4a3d2-3eb6-42a0-957a-56a20afad307.jpg?v=1734942466\" alt=\"Sensor-controlled thermostat for pipe heating cable\" loading=\"lazy\" style=\"display: block; width: 100%; height: auto; margin: 0 0 18px;\" decoding=\"async\"\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ==============================\nImportant Before Ordering\n============================== --\u003e\n\u003cdiv class=\"mk-section\"\u003e\n\u003ch2\u003eImportant Before Ordering\u003c\/h2\u003e\n\u003cdiv class=\"mk-warning-card\"\u003e\n\u003ch3\u003eChoose the Correct Voltage and Connection Type\u003c\/h3\u003e\n\u003cul class=\"mk-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Only:\u003c\/strong\u003e Heating cable is sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120V Plug-In:\u003c\/strong\u003e Includes a grounded input plug and a plug-in output receptacle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e208–240V Hardwired:\u003c\/strong\u003e Does not include a direct power plug or output receptacle.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Load:\u003c\/strong\u003e 15A for both voltage options.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Must Match:\u003c\/strong\u003e The controller, heating cable, and power supply must use the same system voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional Installation:\u003c\/strong\u003e The 208–240V version requires field termination by a qualified electrician.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardwired Connections:\u003c\/strong\u003e Use L1, L2, and Equipment Ground. No Neutral connection is used.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Placement:\u003c\/strong\u003e Secure the sensor against the pipe. Do not place it directly against the heating cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBest for Non-Thermostatic Cable:\u003c\/strong\u003e If the heating cable has its own thermostat, both controls must call for heat before the cable operates.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrdinary Locations Only:\u003c\/strong\u003e Do not install near gasoline, paint, flammable liquids, or explosive vapors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-inline-media\"\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0733\/9684\/6865\/files\/3_339592b4-f58b-43b0-b312-ef2cb1796a2b.jpg?v=1734942481\" alt=\"Adjustable pipe heat tape thermostat temperature settings\" loading=\"lazy\" style=\"display: block; width: 100%; height: auto; margin: 0 0 18px;\" decoding=\"async\"\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ==============================\nSpecifications\n============================== --\u003e\n\u003cdiv class=\"mk-section\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"mk-spec-table-wrapper\"\u003e\n\u003ctable class=\"mk-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e120V Plug-In\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e208–240V Hardwired\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePipe Heat Tape Thermostat Controller\u003c\/td\u003e\n\u003ctd\u003ePipe Heat Tape Thermostat Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e110–120V AC\u003c\/td\u003e\n\u003ctd\u003e208–240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current\u003c\/td\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power\u003c\/td\u003e\n\u003ctd\u003e1800W at 120V\u003c\/td\u003e\n\u003ctd\u003e3120W at 208V \/ 3600W at 240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003eThree-prong grounded plug\u003c\/td\u003e\n\u003ctd\u003eHardwired input leads; no direct plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Output\u003c\/td\u003e\n\u003ctd\u003ePlug-in output receptacle\u003c\/td\u003e\n\u003ctd\u003eHardwired output leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Lead Length\u003c\/td\u003e\n\u003ctd\u003e3 ft\u003c\/td\u003e\n\u003ctd\u003e6 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Type\u003c\/td\u003e\n\u003ctd\u003ePlug-in\u003c\/td\u003e\n\u003ctd\u003eProfessional hardwired installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Setting Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e36°F to 86°F (2°C to 30°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Detection Range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e-4°F to 122°F (-20°C to 50°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault Setting\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e41°F (5°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Differential\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eApproximately ±3.6°F (±2°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Wire Length\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e15 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Display\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eSelectable °F or °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Application\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ePipe heating cable and heat tape temperature control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-inline-media\"\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0733\/9684\/6865\/files\/4_2d884b36-004b-4e6b-8aae-80997633f117.jpg?v=1734942485\" alt=\"Pipe heat tape controller with 15 foot sensor\" loading=\"lazy\" style=\"display: block; width: 100%; height: auto; margin: 0 0 18px;\" decoding=\"async\"\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ==============================\nHow It Works\n============================== --\u003e\n\u003cdiv class=\"mk-collapsible-section\"\u003e\n\u003cdetails class=\"mk-collapsible\"\u003e\n\u003csummary\u003e\u003cspan class=\"mk-collapsible-title\"\u003eHow the Temperature Control Works\u003c\/span\u003e \u003cspan class=\"mk-collapsible-action\"\u003e \u003cspan class=\"mk-collapsible-hint-closed\"\u003eView Details\u003c\/span\u003e \u003cspan class=\"mk-collapsible-hint-open\"\u003eHide Details\u003c\/span\u003e \u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv class=\"mk-collapsible-body\"\u003e\n\u003cp\u003eThe remote sensor measures the temperature at the protected pipe.\u003c\/p\u003e\n\u003cul class=\"mk-list\"\u003e\n\u003cli\u003eThe controller supplies power when the sensor temperature falls below the selected range.\u003c\/li\u003e\n\u003cli\u003ePower stops when the temperature rises above the selected range.\u003c\/li\u003e\n\u003cli\u003eThe switching differential is approximately ±3.6°F (±2°C).\u003c\/li\u003e\n\u003cli\u003eAt a 41°F setting, heating starts near 37°F and stops near 45°F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"mk-feature-grid\"\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003eGreen Indicator\u003c\/h3\u003e\n\u003cp\u003eThe controller is powered on.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003eRed Indicator\u003c\/h3\u003e\n\u003cp\u003eThe connected heating cable is receiving power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003eTemperature Adjustment\u003c\/h3\u003e\n\u003cp\u003eUse the up and down buttons to change the setting.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003e°F \/ °C Selection\u003c\/h3\u003e\n\u003cp\u003ePress and hold the down button for about three seconds.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c!-- ==============================\nInstallation\n============================== --\u003e\n\u003cdiv class=\"mk-collapsible-section\"\u003e\n\u003cdetails class=\"mk-collapsible\"\u003e\n\u003csummary\u003e\u003cspan class=\"mk-collapsible-title\"\u003eBasic Installation Overview\u003c\/span\u003e \u003cspan class=\"mk-collapsible-action\"\u003e \u003cspan class=\"mk-collapsible-hint-closed\"\u003eView Steps\u003c\/span\u003e \u003cspan class=\"mk-collapsible-hint-open\"\u003eHide Steps\u003c\/span\u003e \u003c\/span\u003e\u003c\/summary\u003e\n\u003cdiv class=\"mk-collapsible-body\"\u003e\n\u003cp\u003eInstall the heating cable before connecting it to the controller.\u003c\/p\u003e\n\u003cdiv class=\"mk-feature-grid\"\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003e1. Install the Heating Cable\u003c\/h3\u003e\n\u003cp\u003eFollow the heating cable manufacturer’s instructions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003e2. Position the Sensor\u003c\/h3\u003e\n\u003cp\u003eSecure the sensor against the protected pipe with suitable aluminum foil tape.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003e3. Add Pipe Insulation\u003c\/h3\u003e\n\u003cp\u003eComplete the required insulation without trapping the sensor against the heating cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003e4. Connect the System\u003c\/h3\u003e\n\u003cp\u003eUse the correct procedure for the selected plug-in or hardwired version.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003e5. Set the Temperature\u003c\/h3\u003e\n\u003cp\u003eSelect the required temperature and test the heating output.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-warning-card\"\u003e\n\u003ch3\u003e120V Plug-In Version\u003c\/h3\u003e\n\u003cul class=\"mk-list\"\u003e\n\u003cli\u003eConfirm that the heating cable is rated for 110–120V.\u003c\/li\u003e\n\u003cli\u003eConfirm that the load does not exceed 15A or 1800W.\u003c\/li\u003e\n\u003cli\u003ePlug the heating cable into the controller outlet.\u003c\/li\u003e\n\u003cli\u003ePlug the controller into a properly grounded outlet.\u003c\/li\u003e\n\u003cli\u003eFollow applicable ground-fault protection requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-warning-card\"\u003e\n\u003ch3\u003e208–240V Hardwired Version\u003c\/h3\u003e\n\u003cul class=\"mk-list\"\u003e\n\u003cli\u003eProfessional installation is required.\u003c\/li\u003e\n\u003cli\u003eConfirm the actual supply voltage before wiring.\u003c\/li\u003e\n\u003cli\u003eMatch the controller and heating cable voltage.\u003c\/li\u003e\n\u003cli\u003eConnect L1, L2, and Equipment Ground.\u003c\/li\u003e\n\u003cli\u003eDo not connect a Neutral conductor to the controller.\u003c\/li\u003e\n\u003cli\u003eTerminate the input and output leads inside approved enclosures.\u003c\/li\u003e\n\u003cli\u003eProvide suitable branch-circuit and ground-fault protection.\u003c\/li\u003e\n\u003cli\u003eDo not restore power until all connections are enclosed and inspected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-warning-card\"\u003e\n\u003ch3\u003eSensor Placement\u003c\/h3\u003e\n\u003cul class=\"mk-list\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Heat Tape:\u003c\/strong\u003e Place the sensor directly against the pipe surface.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIn-Pipe Cable:\u003c\/strong\u003e Keep the sensor on the outside bottom surface of the pipe.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvoid Cable Contact:\u003c\/strong\u003e Do not let the sensor touch the heating cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtect the Wire:\u003c\/strong\u003e Do not kink, crush, staple, or clamp the sensor wire.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c!-- ==============================\nApplications\n============================== --\u003e\n\u003cdiv class=\"mk-section\"\u003e\n\u003ch2\u003eRecommended Applications\u003c\/h2\u003e\n\u003cul class=\"mk-list\"\u003e\n\u003cli\u003eExternal pipe heating cable and heat tape\u003c\/li\u003e\n\u003cli\u003eCompatible in-pipe heating cable systems\u003c\/li\u003e\n\u003cli\u003eResidential water pipe freeze protection\u003c\/li\u003e\n\u003cli\u003eBasement and crawl-space pipes\u003c\/li\u003e\n\u003cli\u003eGarage, cabin, barn, and utility-room pipes\u003c\/li\u003e\n\u003cli\u003eIrrigation and light commercial water systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"mk-inline-media\"\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0733\/9684\/6865\/files\/5_85d6ddac-0ebe-4dcb-82ed-fc6504f10ad2.jpg?v=1734942455\" alt=\"Automatic temperature controller for pipe freeze protection\" loading=\"lazy\" style=\"display: block; width: 100%; height: auto; margin: 0;\" decoding=\"async\"\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ==============================\nFAQ\n============================== --\u003e\n\u003cdiv class=\"mk-section mk-faq\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the difference between the two voltage options?\u003c\/summary\u003e\n\u003cp\u003eThe 120V model is plug-in. The 208–240V model has no direct plug or output receptacle and requires professional hardwired installation.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I plug in the 208–240V controller?\u003c\/summary\u003e\n\u003cp\u003eNo. Both the incoming power and heating-cable output require manual field termination.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat heating cable can I use?\u003c\/summary\u003e\n\u003cp\u003eUse a compatible heating cable with the same voltage as the selected controller. The total load must not exceed 15A.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan it control a cable with a built-in thermostat?\u003c\/summary\u003e\n\u003cp\u003eYes, but both thermostats must call for heat before the cable operates. It is usually best suited to heating cable without built-in temperature control.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes it measure room temperature or pipe temperature?\u003c\/summary\u003e\n\u003cp\u003eIt measures the temperature at the end of the 15 ft wired sensor. Place the sensor directly against the protected pipe.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan the sensor touch the heating cable?\u003c\/summary\u003e\n\u003cp\u003eNo. Direct contact may create an inaccurate reading and improper switching.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan it control both external and in-pipe heating cables?\u003c\/summary\u003e\n\u003cp\u003eYes, when the cable voltage and load are compatible. The controller and sensor always remain outside the pipe.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWill it restart after a power outage?\u003c\/summary\u003e\n\u003cp\u003eIt retains the previous power status and temperature setting after power is restored.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes this controller replace pipe insulation?\u003c\/summary\u003e\n\u003cp\u003eNo. Proper heating cable installation and suitable pipe insulation are still required.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c!-- ==============================\nGuides\n============================== --\u003e\n\u003cdiv class=\"mk-section\"\u003e\n\u003ch2\u003eGuides \u0026amp; Resources\u003c\/h2\u003e\n\u003cdiv class=\"mk-support\"\u003e\n\u003ch2\u003eCheck Before Connecting Power\u003c\/h2\u003e\n\u003cul class=\"mk-list\"\u003e\n\u003cli\u003eMatch the controller, heating cable, and supply voltage.\u003c\/li\u003e\n\u003cli\u003eKeep the total connected load below 15A.\u003c\/li\u003e\n\u003cli\u003eInstall the heating cable before connecting the controller.\u003c\/li\u003e\n\u003cli\u003eSecure the sensor against the pipe.\u003c\/li\u003e\n\u003cli\u003eKeep the sensor separated from the heating cable.\u003c\/li\u003e\n\u003cli\u003eUse suitable circuit and ground-fault protection.\u003c\/li\u003e\n\u003cli\u003eUse a qualified electrician for the 208–240V version.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRead the complete controller manual and heating cable instructions before installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ==============================\nProduct Images\n============================== --\u003e\n\u003c\/div\u003e","brand":"MAXKOSKO","offers":[{"title":"120V Plug-In","offer_id":54577920606481,"sku":"Y-PHC","price":62.99,"currency_code":"USD","in_stock":true},{"title":"240V Hardwired","offer_id":54577920639249,"sku":"Y-PHC-240V","price":62.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/9684\/6865\/files\/MK-PHC.jpg?v=1734671073","url":"https:\/\/maxkosko.com\/zh\/products\/thermostat-for-pipe-heat-tape","provider":"MAXKOSKO","version":"1.0","type":"link"}