{"product_id":"uncoupling-membrane-for-floor-warming-cable","title":"MAXKOSKO Uncoupling Membrane for Floor Warming, Waterproofing \u0026 Crack Prevention","description":"\u003cdiv class=\"mk-product-content\"\u003e\n\u003c!-- ==============================\n  Overview\n  ============================== --\u003e\n\u003cdiv class=\"mk-overview\"\u003e\n\u003ch2\u003eUncoupling Membrane for Electric Floor Heating Cable\u003c\/h2\u003e\n\u003cp\u003eMAXKOSKO Electric Floor Heating Uncoupling Membrane combines heating cable management, tile crack protection, waterproofing support, and load distribution in one underlayment system.\u003c\/p\u003e\n\u003cp\u003eThe raised stud pattern securely holds compatible electric floor heating cables with diameters from 3.8 to 5.0 mm. Installers can route the cable directly into the membrane channels without separate clips or fasteners, helping create customized heated zones beneath tile floors.\u003c\/p\u003e\n\u003cp\u003eUnlike standard tile underlayment membranes, this product is specifically designed to work with loose electric floor heating cable while also helping reduce stress transfer between the subfloor and finished tile covering.\u003c\/p\u003e\n\u003cp\u003eLooking for an uncoupling membrane without heating cable channels? Compare our \u003ca href=\"https:\/\/maxkosko.com\/products\/tile-crack-prevention-underlayment-mat\"\u003e basic non-adhesive membrane \u003c\/a\u003e, \u003ca href=\"https:\/\/maxkosko.com\/products\/self-adhesive-uncoupling-membrane\"\u003e self-adhesive membrane \u003c\/a\u003e, or \u003ca href=\"https:\/\/maxkosko.com\/products\/double-fleece-tile-uncoupling-membrane\"\u003e double-fleece membrane \u003c\/a\u003e.\u003c\/p\u003e\n\u003cdiv class=\"mk-feature-grid\"\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003eBuilt-In Cable Channels\u003c\/h3\u003e\n\u003cp\u003eThe raised stud pattern securely holds compatible electric floor heating cable without separate clips or fasteners.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003e3.8–5.0 mm Cable Compatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned for many loose electric floor heating cables within the specified diameter range.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003eCustom Heating Layouts\u003c\/h3\u003e\n\u003cp\u003eRoute the cable through the membrane channels to create heating zones based on the room layout.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003eUncoupling Protection\u003c\/h3\u003e\n\u003cp\u003eHelps reduce stress transfer caused by minor movement between the substrate and tiled surface.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003eWaterproof Membrane\u003c\/h3\u003e\n\u003cp\u003eThe polyethylene-based construction helps protect moisture-sensitive substrates when properly sealed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003eLoad Distribution\u003c\/h3\u003e\n\u003cp\u003eMortar-filled cavities help transfer loads evenly from the tile covering to the supporting substrate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-inline-media\"\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0733\/9684\/6865\/files\/1_8f9a3ccb-8997-47ad-9b3e-8bae23a489b3.png?v=1763969047\" alt=\"MAXKOSKO uncoupling membrane for electric floor heating cable\" style=\"width: 100%; height: auto; display: block;\" loading=\"lazy\" decoding=\"async\"\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ==============================\n  Important Before Ordering\n  ============================== --\u003e\n\u003cdiv class=\"mk-section\"\u003e\n\u003ch2\u003eImportant Before Ordering\u003c\/h2\u003e\n\u003cdiv class=\"mk-warning-card\"\u003e\n\u003ch3\u003eConfirm Your Floor Heating System\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHeating Cable Size: \u003c\/strong\u003eUse only compatible electric floor heating cable with an outside diameter between 3.8 and 5.0 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLoose Cable Systems: \u003c\/strong\u003eThe membrane channels are designed to hold loose heating cable. Confirm compatibility before using heating mats, foils, or other heating products.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMembrane Only: \u003c\/strong\u003eHeating cable, thermostat, floor sensor, mortar, and tile are not included unless specifically stated in the selected product option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo Not Cut the Heating Cable: \u003c\/strong\u003ePlan the heated area and cable spacing according to the heating cable manufacturer’s instructions. Never shorten or modify a fixed-length heating cable unless expressly permitted.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Installation: \u003c\/strong\u003eHeating cable resistance, insulation, grounding, sensor placement, and electrical connections must follow the heating system instructions and applicable electrical codes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSubfloor Condition: \u003c\/strong\u003eThe substrate must be structurally sound, flat, clean, and suitable for a mortar-bonded tile installation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ==============================\n  Designed for Heated Tile Floors\n  ============================== --\u003e\n\u003cdiv class=\"mk-section\"\u003e\n\u003ch2\u003eDesigned for Heated Tile Floors\u003c\/h2\u003e\n\u003cp\u003eThis membrane provides a dedicated installation surface for loose electric floor heating cable while maintaining the uncoupling and waterproofing functions required beneath many tiled floors.\u003c\/p\u003e\n\u003cdiv class=\"mk-feature-grid\"\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003eSecure Cable Placement\u003c\/h3\u003e\n\u003cp\u003eThe cable presses between the raised studs and remains positioned while mortar and tile are installed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003eNo Separate Fasteners\u003c\/h3\u003e\n\u003cp\u003eBuilt-in channels reduce the need for cable clips, straps, or additional fastening accessories.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003eFlexible Heating Zones\u003c\/h3\u003e\n\u003cp\u003eLoose cable can be routed around permanent fixtures and focused in areas where floor warmth is needed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-feature-card\"\u003e\n\u003ch3\u003eLow-Profile Assembly\u003c\/h3\u003e\n\u003cp\u003eThe approximately 0.22-inch membrane thickness helps limit added floor height beneath the tile assembly.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-inline-media\"\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0733\/9684\/6865\/files\/2_e3b9475d-2a42-4cd7-a029-d5dee6598a04.jpg?v=1763969047\" alt=\"Electric floor heating cable installed in uncoupling membrane channels\" style=\"width: 100%; height: auto; display: block;\" loading=\"lazy\" decoding=\"async\"\u003e\u003c\/figure\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0733\/9684\/6865\/files\/3_38d47f0b-69bf-4e65-8f7c-882475a12086.jpg?v=1763969048\" alt=\"Raised stud design for securing electric floor heating cable\" style=\"width: 100%; height: auto; display: block;\" loading=\"lazy\" decoding=\"async\"\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ==============================\n  Applications\n  ============================== --\u003e\n\u003cdiv class=\"mk-section\"\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eMAXKOSKO Heating Cable Uncoupling Membrane is intended for interior electric floor heating installations beneath compatible tile coverings.\u003c\/p\u003e\n\u003cul class=\"mk-list\"\u003e\n\u003cli\u003eHeated bathroom and shower-area tile floors\u003c\/li\u003e\n\u003cli\u003eKitchen and dining area floor warming\u003c\/li\u003e\n\u003cli\u003eBasement and laundry room tile floors\u003c\/li\u003e\n\u003cli\u003eEntryways, mudrooms, and other cold tiled areas\u003c\/li\u003e\n\u003cli\u003eResidential renovation and new construction projects\u003c\/li\u003e\n\u003cli\u003eCeramic, porcelain, and approved natural stone tile\u003c\/li\u003e\n\u003cli\u003eProperly prepared plywood, OSB, concrete, and approved substrates\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"mk-warning-card\"\u003e\n\u003ch3\u003eApplication Limits\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFloor Use: \u003c\/strong\u003eThis membrane is primarily designed for floor heating applications beneath tile.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWet Areas: \u003c\/strong\u003eA complete waterproof assembly requires proper sealing of seams, corners, penetrations, and floor-to-wall transitions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFloor Covering Compatibility: \u003c\/strong\u003eConfirm that the selected tile, mortar, heating cable, and substrate are approved for use together.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-inline-media\"\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0733\/9684\/6865\/files\/6_37d30449-d030-4fce-8095-b952ec5f9996.jpg?v=1763969047\" alt=\"Electric heated tile floor membrane applications\" style=\"width: 100%; height: auto; display: block;\" loading=\"lazy\" decoding=\"async\"\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ==============================\n  Specifications\n  ============================== --\u003e\n\u003cdiv class=\"mk-section\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"mk-spec-table-wrapper\"\u003e\n\u003ctable class=\"mk-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eElectric Floor Heating Uncoupling Membrane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Use\u003c\/td\u003e\n\u003ctd\u003eSecuring Loose Electric Floor Heating Cable Beneath Tile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Cable Diameter\u003c\/td\u003e\n\u003ctd\u003e3.8–5.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMembrane Thickness\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.22 in (5.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eHDPE and PP Composite Construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Method\u003c\/td\u003e\n\u003ctd\u003eMortar-Bonded to the Prepared Subfloor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Cable Retention\u003c\/td\u003e\n\u003ctd\u003eRaised Stud and Channel Design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Functions\u003c\/td\u003e\n\u003ctd\u003eCable Management, Uncoupling, Waterproofing Support, Vapor Management and Load Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Tile Types\u003c\/td\u003e\n\u003ctd\u003eCeramic, Porcelain and Approved Natural Stone Tile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Substrates\u003c\/td\u003e\n\u003ctd\u003eConcrete, Plywood, OSB and Other Approved Tile Substrates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf-Adhesive Backing\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Cable Included\u003c\/td\u003e\n\u003ctd\u003eNo, Unless Specifically Stated in the Selected Option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-inline-media\"\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0733\/9684\/6865\/files\/4_a3cab30d-99e4-42fc-a38b-b0b164cedb3c.jpg?v=1763969046\" alt=\"Waterproof electric floor heating uncoupling membrane structure\" style=\"width: 100%; height: auto; display: block;\" loading=\"lazy\" decoding=\"async\"\u003e\u003c\/figure\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0733\/9684\/6865\/files\/6-1.jpg?v=1763969048\" alt=\"MAXKOSKO electric floor heating uncoupling membrane product details\" style=\"width: 100%; height: auto; display: block;\" loading=\"lazy\" decoding=\"async\"\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ==============================\n  Product Comparison\n  ============================== --\u003e\n\u003cdiv class=\"mk-section\"\u003e\n\u003ch2\u003eCompare MAXKOSKO Uncoupling Membranes\u003c\/h2\u003e\n\u003cp\u003eThis heating membrane is designed for a different purpose than the three standard tile underlayment options. Choose it when the project includes loose electric floor heating cable.\u003c\/p\u003e\n\u003cdiv class=\"mk-spec-table-wrapper\"\u003e\n\u003ctable class=\"mk-spec-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct\u003c\/td\u003e\n\u003ctd\u003eKey Design\u003c\/td\u003e\n\u003ctd\u003eBest For\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/maxkosko.com\/products\/tile-crack-prevention-underlayment-mat\"\u003e Basic Tile Underlayment Mat \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard non-adhesive uncoupling membrane\u003c\/td\u003e\n\u003ctd\u003eEconomical crack protection for general tile floors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/maxkosko.com\/products\/self-adhesive-uncoupling-membrane\"\u003e Self-Adhesive Uncoupling Membrane \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePeel-and-stick backing\u003c\/td\u003e\n\u003ctd\u003eFaster installation without mortar beneath the membrane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/maxkosko.com\/products\/double-fleece-tile-uncoupling-membrane\"\u003e Double-Fleece Uncoupling Membrane \u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eFleece bonding layers on both sides\u003c\/td\u003e\n\u003ctd\u003eEnhanced mechanical bonding and vapor management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectric Floor Heating Uncoupling Membrane\u003c\/td\u003e\n\u003ctd\u003eRaised channels that retain loose heating cable\u003c\/td\u003e\n\u003ctd\u003eElectric heated tile floors using 3.8–5.0 mm cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-warning-card\"\u003e\n\u003ch3\u003eQuick Selection Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eChoose the Basic Membrane: \u003c\/strong\u003e For economical tile crack protection without adhesive or heating cable channels. \u003ca href=\"https:\/\/maxkosko.com\/products\/tile-crack-prevention-underlayment-mat\"\u003e View Product \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChoose the Self-Adhesive Membrane: \u003c\/strong\u003e For faster peel-and-stick floor preparation. \u003ca href=\"https:\/\/maxkosko.com\/products\/self-adhesive-uncoupling-membrane\"\u003e View Product \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChoose the Double-Fleece Membrane: \u003c\/strong\u003e For mortar-based installation with reinforced mechanical bonding. \u003ca href=\"https:\/\/maxkosko.com\/products\/double-fleece-tile-uncoupling-membrane\"\u003e View Product \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChoose the Heating Cable Membrane: \u003c\/strong\u003eWhen the tile floor will include compatible loose electric floor heating cable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ==============================\n  Installation\n  ============================== --\u003e\n\u003cdiv class=\"mk-section\"\u003e\n\u003ch2\u003eBasic Installation Overview\u003c\/h2\u003e\n\u003cp\u003eApply compatible thin-set mortar to the prepared subfloor and embed the membrane into the fresh mortar. Press the heating cable into the designated channels according to the approved cable layout, then cover the system with suitable mortar and install the tile.\u003c\/p\u003e\n\u003cdiv class=\"mk-warning-card\"\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTest the Cable: \u003c\/strong\u003eMeasure and record cable resistance before installation, after placing the cable, and before installing the finished flooring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProtect the Cable: \u003c\/strong\u003eDo not nick, crush, overlap, cross, or sharply bend the heating cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSensor Placement: \u003c\/strong\u003eInstall the floor sensor between adjacent cable runs without allowing it to touch or cross the heating cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo Not Use Self-Leveling Compound Over the Membrane: \u003c\/strong\u003eComplete any required floor leveling before installing the membrane unless the relevant system manufacturer specifically approves another method.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFollow System Instructions: \u003c\/strong\u003eAlways follow the heating cable, thermostat, mortar, tile, and membrane installation requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mk-inline-media\"\u003e\n\u003cfigure\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0733\/9684\/6865\/files\/5_18d05499-cafb-4b6b-9ed9-3687e27d3109.jpg?v=1763969046\" alt=\"MAXKOSKO heating cable uncoupling membrane installation\" style=\"width: 100%; height: auto; display: block;\" loading=\"lazy\" decoding=\"async\"\u003e\u003c\/figure\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- ==============================\n  FAQ\n  ============================== --\u003e\n\u003cdiv class=\"mk-section mk-faq\"\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat size heating cable fits this membrane?\u003c\/summary\u003e\n\u003cp\u003eThe membrane is designed for compatible loose electric floor heating cables with an outside diameter between 3.8 and 5.0 mm.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the membrane include heating cable?\u003c\/summary\u003e\n\u003cp\u003eNo. This product is the uncoupling membrane only unless the selected product option specifically states that heating cable or other components are included.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I use any electric floor heating cable?\u003c\/summary\u003e\n\u003cp\u003eMany loose heating cables within the specified diameter range may fit, but compatibility must also be confirmed with the cable manufacturer. Check cable diameter, minimum spacing, bend radius, watt density, voltage, and installation requirements before ordering.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eDoes the cable require separate clips or fasteners?\u003c\/summary\u003e\n\u003cp\u003eNo. The raised membrane channels are designed to grip compatible heating cable and hold it in position during installation.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan I change the heating cable spacing?\u003c\/summary\u003e\n\u003cp\u003eThe channel layout allows flexible cable routing, but the actual spacing must remain within the limits specified by the heating cable manufacturer. Do not place cable closer together to increase heat output.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat type of thin-set mortar should be used?\u003c\/summary\u003e\n\u003cp\u003eProduct guidance recommends modified thin-set mortar meeting ANSI A118.11 for bonding the membrane to compatible wood or concrete substrates and unmodified thin-set mortar meeting ANSI A118.1 above the membrane. Always verify compatibility with the substrate, tile, heating cable, and mortar manufacturers.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan self-leveling compound be applied over the membrane?\u003c\/summary\u003e\n\u003cp\u003eIt is generally not recommended. Complete necessary floor leveling before installing the membrane unless the membrane and heating system manufacturers specifically approve another installation method.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eHow is this different from the other MAXKOSKO membranes?\u003c\/summary\u003e\n\u003cp\u003eThis version includes raised channels that hold loose electric floor heating cable. The other three membranes are primarily intended for tile crack protection and do not provide dedicated cable-retention channels.\u003c\/p\u003e\n\u003cp\u003eCompare the \u003ca href=\"https:\/\/maxkosko.com\/products\/tile-crack-prevention-underlayment-mat\"\u003e basic membrane \u003c\/a\u003e, \u003ca href=\"https:\/\/maxkosko.com\/products\/self-adhesive-uncoupling-membrane\"\u003e self-adhesive membrane \u003c\/a\u003e, and \u003ca href=\"https:\/\/maxkosko.com\/products\/double-fleece-tile-uncoupling-membrane\"\u003e double-fleece membrane \u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003c\/div\u003e\n\u003c!-- ==============================\n  Guides and Resources\n  ============================== --\u003e\n\u003c\/div\u003e","brand":"MAXKOSKO","offers":[{"title":"54 Sq. Ft.","offer_id":44731678884113,"sku":"54 Sq.Ft. Membrane","price":109.99,"currency_code":"USD","in_stock":true},{"title":"108 Sq. Ft.","offer_id":44731678916881,"sku":"108 Sq.Ft. Membrane","price":204.99,"currency_code":"USD","in_stock":true},{"title":"140 Sq. Ft.","offer_id":46442497671441,"sku":"140 Sq.Ft. Membrane","price":269.99,"currency_code":"USD","in_stock":false},{"title":"161 Sq. Ft.","offer_id":44731678949649,"sku":"161 Sq.Ft. Membrane","price":314.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/9684\/6865\/files\/2_ec0f3dbe-fb60-44d3-95f0-6144d7baddf4.jpg?v=1763969005","url":"https:\/\/maxkosko.com\/zh\/products\/uncoupling-membrane-for-floor-warming-cable","provider":"MAXKOSKO","version":"1.0","type":"link"}