Skip to content
Skip to product information
1 of 9

MAXKOSKO Roof & Pipe Heating Cable, 7W/ft, 10ft to 150ft Self-Regulating with 10ft Cord

$69.99 USD
$69.99 USD $22.99 USD
Sold out

6 in stock

Size: 75 ft

Payment Reminder

  1. Our website accepts Visa, MasterCard, and American Express. If you are using a card issued by another bank, please ensure it is enabled for international transactions.
  2. During payment, you may be required to complete 3D Secure (3DS) verification. Please ensure that the cardholder completes the verification to avoid payment failure.
  3. If your usual spending amounts are relatively low and you are making a larger purchase, your bank may flag the transaction as a potential risk. If your payment fails, please contact your bank to approve the transaction.
  • Delivery: 7-11/5-8 working days.
  • Customer Support: Response within 24 hours!
  • Customization available: Bulk orders & size customization accepted.
View Product Details

7W/ft Self-Regulating Heat Cable for Pipes, Roofs & Gutters

MAXKOSKO Preassembled Self-Regulating Heat Cable provides one flexible solution for water pipe freeze protection and roof, gutter, and downspout de-icing.

The 120V cable automatically adjusts its heat output along the heating section as surrounding temperatures change. Each fixed-length cable includes an additional 10 ft power cord with a lighted plug.

Your selected length refers to the heating cable section only. The 10 ft power cord is additional and is not deducted from the selected heating length.

Dual-Purpose Protection

Suitable for compatible water pipes, roof edges, gutters, downspouts, valleys, and other exposed freeze-prone areas.

Self-Regulating Output

Produces more heat in colder conditions and reduces output as the surrounding temperature becomes warmer.

7W/ft Rated Output

Rated at approximately 7 watts per foot at 50°F (10°C) for demanding outdoor freeze protection.

10 ft Power Cord

Provides additional reach between the heating section and a suitable grounded 120V outlet.

Important Before Ordering

Choose the Length and Application Carefully

Fixed-Length Cable: The heating cable is factory assembled and sealed. Do not cut, shorten, splice, repair, paint, glue, or otherwise modify it.

Self-Regulating Is Not Auto-Off: The cable adjusts its heat output but may continue drawing power. Disconnect it during warm weather or use a compatible automatic controller.

Pipe Installation Requires Insulation: Suitable pipe insulation and a weather-resistant outer covering are required separately for reliable pipe freeze protection.

Roof Accessories Sold Separately: Roof clips, cable spacers, downspout hangers, and other roof-specific attachment hardware are not included.

Plan One Complete Route: Select enough cable for the entire pipe or roof route. Do not cut the cable to serve separate areas.

120V GFCI Protection Required: Use a grounded, weather-protected 120V outlet with code-compliant ground-fault protection. Do not use an extension cord.

Choose Your Application

Water Pipe Freeze Protection

Suitable for compatible metal and plastic water pipes, including PVC and polyethylene. Install straight or spiral the cable according to pipe size, cable length, and insulation requirements.

Roof & Gutter De-Icing

Helps create a drainage path for melting snow and ice along roof edges, gutters, downspouts, valleys, and selected problem areas.

Understand What the Cable Does

For Pipes: The cable helps reduce the risk of water pipes freezing. Correct sizing, sensor or controller use, insulation, and electrical protection remain essential.

For Roofs: The cable helps maintain meltwater drainage. It does not remove accumulated roof snow or eliminate an ice dam that has already formed.

Specifications

Product Type Preassembled Dual-Purpose Self-Regulating Heat Cable
Rated Voltage 120V AC
Rated Heat Output Approximately 7W/ft at 50°F (10°C)
Power Cord Length 10 ft, Additional to the Selected Heating Length
Plug Grounded Plug with Power Indicator Light
Pipe Applications Compatible Metal and Plastic Water Pipes
Roof Applications Roof Edges, Gutters, Downspouts, Valleys and Selected Problem Areas
Compatible Roof Surfaces Compatible Shingle, Slate, Metal, Wood and Selected Flat or Membrane Roof Systems
Minimum Installation Temperature -22°F (-30°C)
Cable Modification Cannot Be Cut, Shortened or Spliced
Pipe Insulation Required and Sold Separately
Roof Installation Hardware Sold Separately
Selecting the Right Cable Length View Guide Hide Guide

For Water Pipes

  • Measure the full pipe length, including valves and other exposed components.
  • Confirm the pipe material, outside diameter, lowest expected temperature, and insulation thickness.
  • If the cable is longer than the pipe, follow the manual for approved spiral or multiple-pass installation.
  • Do not leave heated cable coiled during operation.

For Roofs and Gutters

  • Include the roof-edge pattern, gutters, downspouts, valleys, dormers, and other problem areas.
  • Gutters and downspouts may require a double cable run.
  • Use a separate cable when protected areas are too far apart for one safe continuous route.
  • Review the manual’s roof-layout and length-calculation tables before ordering.
Basic Installation Requirements View Requirements Hide Requirements
  • Inspect the complete cable before installation and do not use it if damaged.
  • Do not sharply bend, crush, staple, pierce, or place excessive tension on the cable.
  • For pipe use, secure the cable to the pipe and install suitable thermal insulation afterward.
  • For roof use, mount the cable on the exposed roof surface using approved roof-specific hardware.
  • Do not install the heating cable beneath shingles or other roofing materials.
  • Keep the power connection protected from water and form a drip loop where required.
  • Test the system before winter and inspect it again at the beginning of each heating season.
  • Read the complete installation manual before installing or powering the cable.

Frequently Asked Questions

Can the same cable model be used for both pipes and roofs?

Yes. This model is designed for compatible water pipe freeze protection and roof, gutter, and downspout de-icing. The installation method and required accessories differ by application.

Does the selected length include the 10 ft power cord?

No. The selected size refers to the heating section. The attached 10 ft power cord provides additional non-heating reach.

Can I cut the cable if it is too long?

No. The cable is factory assembled and sealed. Do not cut, shorten, splice, repair, or otherwise modify the heating section.

Does self-regulating cable turn itself completely off?

No. It adjusts its heat output as temperature changes but may continue consuming power. Disconnect it during warm weather or use a compatible automatic controller.

Can it be installed on an empty water pipe?

The self-regulating cable adjusts its output along the pipe, but the complete installation must still follow the pipe material, insulation, temperature, and electrical requirements in the manual.

Is pipe insulation included?

No. Suitable thermal insulation and weather-resistant protection must be purchased separately.

Are roof clips and spacers included?

No. Compatible roof clips, cable spacers, downspout hangers, and any roof-specific attachment materials are sold separately.

Can the cable be installed underneath shingles?

No. The heating cable should remain exposed and accessible on the roof surface. Approved clips may attach beneath compatible shingle tabs, but the heating cable itself should not be buried beneath the roofing material.

Before Ordering

Confirm the application, total route length, pipe or roof material, required insulation or attachment hardware, available outlet location, and ground-fault protection before selecting a cable size.

Refer to the complete installation manual for pipe sizing tables, insulation requirements, roof layout calculations, testing, and seasonal maintenance.

MAXKOSKO self-regulating heat cable for pipes roofs and gutters 7 watt per foot self-regulating pipe and roof heating cable Self-regulating heat cable for metal and plastic water pipes Pipe heating cable straight trace and spiral installation options Roof and gutter de-icing cable installation applications Heavy-duty dual-purpose heating cable construction MAXKOSKO preassembled heating cable with ten foot power cord

Questions & Answers

Have a Question?

Ask a Question
  • I need heat tape to keep my gutters from freezing. Do you recommend a double strand of tape in the gutter? does it need clips to keep the strands seperated?

    Hi Chris,
    Thank you for considering our heating tape for your gutter heating needs. 
    We recommend using our Roof Deicing Heating Cable, which you can find at the following link: 
    Roof De-icing Heating Cable]
     
    If you choose to use a double strand of tape in the gutter, it can provide added effectiveness in preventing freezing. 
    However, it's important to calculate the required length of the heating cable accurately.
     
    Regarding clips to keep the strands separated, you may consider using them.
     
    Should you have any further questions or need assistance with sizing, feel free to let us know. We're here to help.